Dural Changes Induced by an Ultrasonic Bone Curette in an Excised Porcine Spinal Cord
http://hdl.handle.net/10458/0002000300
http://hdl.handle.net/10458/00020003002d9d18a4-18f9-44f0-ba20-a1d5f8bd3cb6
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2023-11-07 | |||||
タイトル | ||||||
タイトル | Dural Changes Induced by an Ultrasonic Bone Curette in an Excised Porcine Spinal Cord | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
キーワード | cotton pattie | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
キーワード | dura | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
キーワード | spinal cord | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
キーワード | ultrasonic bone curette | |||||
資源タイプ | ||||||
資源タイプ | journal article | |||||
著者 |
太田, 理造
× 太田, 理造× Iwaki, Eri× 境, 健太郎× 原口, 智宏× 金子, 泰之× 関口, 敏× 山口, 良二× 永延, 清和 |
|||||
著者ID | ||||||
内容記述 | Citation: | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In spinal surgery, ultrasonic bone curettes are considered unlikely to cause mechanical injury to the dura; however, there is little evidence to support this claim. We investigated the effect of direct contact with an ultrasonic bone curette on the dura and the protective effect of covering the dura with a cotton pattie using an excised porcine spinal cord. The ultrasonic bone curette was pressed against the porcine spinal cord with constant force and activated for 1 s, with or without covering the dura with a cotton pattie. The dural surface and cross-section were observed using electron and light microscopy. When the ultrasonic bone curette was applied directly against the dura, most specimens showed non-perforating dural injuries. However, none of the specimens showed dural perforation. Histological changes were also observed. The use of a cotton pattie reduced the occurrence of these changes, although it did not prevent them when ultrasonic vibration was applied with a large force. We considered ultrasonic bone curettes to have a low risk of dural perforation and, thus, to be a safe surgical device as long as they did not accidentally make strong contact with the dura. | |||||
言語 | en | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Citation: Ota R, Iwaki E, Sakai K, Haraguchi T, Kaneko Y, Sekiguchi S, Yamaguchi R, Naganobu K. Dural Changes Induced by an Ultrasonic Bone Curette in an Excised Porcine Spinal Cord. Vet Sci. 2022 Oct 28;9(11):601. doi: 10.3390/vetsci9110601. PMID: 36356078; PMCID: PMC9694971. |
|||||
言語 | en | |||||
書誌情報 |
en : Veterinary Sciences 巻 9, 号 11, p. 601, 発行日 2022-10-28 |
|||||
出版者 | ||||||
出版者 | MDPI | |||||
言語 | en | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.3390/vetsci9110601 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | © 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). | |||||
著者版フラグ | ||||||
出版タイプ | VoR |