{"created":"2023-05-15T10:01:47.019193+00:00","id":6442,"links":{},"metadata":{"_buckets":{"deposit":"dde8ed8c-7fc4-46f7-bc82-fd5fc7f1c39c"},"_deposit":{"created_by":5,"id":"6442","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"6442"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00006442","sets":["73","73:36","73:36:330","73:36:330:484"]},"author_link":["13738","33746","13733","33745"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-09-28","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"278","bibliographicPageStart":"275","bibliographicVolumeNumber":"50","bibliographic_titles":[{"bibliographic_title":"宮崎大学工学部紀要","bibliographic_titleLang":"ja"},{"bibliographic_title":"Memoirs of Faculty of Engineering, University of Miyazaki","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Instead of measuring the backsheet temperature, the temperature of the solar cell in a PV module structure should be known because the solar cell temperature determines the temperature characteristics of the PV module. As the backsheet temperature is easily obtained, it is generally used as the module temperature; however, it is significantly affected by wind and does not accurately indicate the solar cell temperature inside the PV module. By covering a thermocouple for measuring the backsheet temperature with a polyethylene foam, the effect of wind on the measured temperature can be suppressed significantly.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宮崎大学工学部","subitem_publisher_language":"ja"},{"subitem_publisher":"Faculty of Engineering, University of Miyazaki","subitem_publisher_language":"en"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00732558","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"05404924","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"前田, 進行","creatorNameLang":"ja"},{"creatorName":"マエダ, ミチユキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"33745","nameIdentifierScheme":"WEKO"}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"0000000106573887","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"https://isni.org/isni/0000000106573887"}],"affiliationNames":[{"affiliationName":"宮崎大学","affiliationNameLang":"ja"},{"affiliationName":"University of Miyazaki","affiliationNameLang":"en"}]}],"creatorNames":[{"creatorName":"西岡, 賢祐","creatorNameLang":"ja"},{"creatorName":"ニシオカ, ケンスケ","creatorNameLang":"ja-Kana"},{"creatorName":"Nishioka , Kensuke","creatorNameLang":"en"}],"familyNames":[{"familyName":"西岡","familyNameLang":"ja"},{"familyName":"ニシオカ","familyNameLang":"ja-Kana"},{"familyName":"Nishioka ","familyNameLang":"en"}],"givenNames":[{"givenName":"賢祐","givenNameLang":"ja"},{"givenName":"ケンスケ","givenNameLang":"ja-Kana"},{"givenName":"Kensuke","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13733","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"00377441","nameIdentifierScheme":"e-Rad_Researcher","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=00377441"}]},{"creatorNames":[{"creatorName":"Maeda, Michiyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"33746","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nishioka, Kensuke","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"13738","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-11-04"}],"displaytype":"detail","filename":"Engineering_50_p275-p278.pdf","filesize":[{"value":"2.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文","url":"https://miyazaki-u.repo.nii.ac.jp/record/6442/files/Engineering_50_p275-p278.pdf"},"version_id":"8c402a3d-30b4-4ec2-9733-e3cf8235bfb6"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Photovoltaic module","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Measurement","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Temperature","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"wind","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Irradiance","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"最小誤差を実現する太陽電池モジュール温度計測方法の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"最小誤差を実現する太陽電池モジュール温度計測方法の検討","subitem_title_language":"ja"},{"subitem_title":"Examination of solar cell module temperature measurement method to realize the minimum error","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"5","path":["73","36","330","484"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2021-11-04"},"publish_date":"2021-11-04","publish_status":"0","recid":"6442","relation_version_is_last":true,"title":["最小誤差を実現する太陽電池モジュール温度計測方法の検討"],"weko_creator_id":"5","weko_shared_id":-1},"updated":"2025-01-14T00:50:17.995765+00:00"}