WEKO3
アイテム
Voltage Profi les on HV Distribution Lines with Various Network Confi gurations and Customers
http://hdl.handle.net/10458/00010276
http://hdl.handle.net/10458/00010276f795b81f-1cd5-4684-97ff-d5b755ec681a
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-10-26 | |||||
タイトル | ||||||
タイトル | Voltage Profi les on HV Distribution Lines with Various Network Confi gurations and Customers | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | high voltage distribution line | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | PV system installation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | voltage variation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | shunt capacitor | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | static voltage regulator | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
Khaing, May Thin
× Khaing, May Thin× 迫田, 達也× Hayashi, Noriyuki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Electrical power system reliability is a critical issue for utilities and power loss occurred in transmission and distribution network is a must consideration. Electrical distribution system is the largest portion of network in the electrical power system. There is voltage drop on long HV distribution line (D/L) due to heavy load consumption, absent of voltage regulation, as well as poor power factor collection on long HV D/L. Therefore, phase advancing capacitors (Shunt Capacitor, SCs) are installed in parallel with customer loads for voltage improvement and power factor correction. However, these SCs, sometimes, lead to Ferranti effect, especially at the very lightly loaded condition. Moreover, in recent years, the introduction of photovoltaic power generation systems (PV systems) into HV D/L has developed rapidly and may cause the unacceptable voltage variation on HV D/L. In this study, a virtual 6.6 kV long distance (20 km) HV D/L without PV system supported from Kyushu Electric Power Company (Qden) in Miyazaki branch, is introduced. In this long distance HV D/L, a 20 MVA transformer, three static voltage regulators (SVRs), and 50 customer loads are included. For very lightly loaded condition, the effects of SCs detachment area on the voltage profiles of HV D/L are numerically investigated and discussed. Moreover, the optimal location is proposed to change the suitable SVR for the purpose of upgrading voltage drop in heavy loaded condition. Then, voltage profiles of different lengths (20.3 km for long and 8.70 km for short) HV D/Ls with PV system installing SCs at customer’s side and different load capacity are discussed. Furthermore, the conditions of flowing line current on HV D/L with PV system for different load locations are explained with phasor diagram. A program based on the Newton Raphson method was coded for the power flow calculation. |
|||||
言語 | en | |||||
書誌情報 |
ja : 宮崎大学工学部紀要 en : Memoirs of Faculty of Engineering, University of Miyazaki 巻 50, p. 95-103, 発行日 2021-09-28 |
|||||
出版者 | ||||||
出版者 | 宮崎大学工学部 | |||||
言語 | ja | |||||
出版者 | ||||||
出版者 | Faculty of Engineering, University of Miyazaki | |||||
言語 | en | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 05404924 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00732558 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |