{"created":"2023-05-15T10:01:36.789408+00:00","id":6225,"links":{},"metadata":{"_buckets":{"deposit":"b6fbbfc4-20e7-4932-b3fe-1f73dcbe4f75"},"_deposit":{"created_by":5,"id":"6225","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"6225"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00006225","sets":["73","73:36","73:36:330","73:36:330:469"]},"author_link":["33138","14214","12874","13738","33139"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"127","bibliographicPageStart":"119","bibliographicVolumeNumber":"49","bibliographic_titles":[{"bibliographic_title":"宮崎大学工学部紀要","bibliographic_titleLang":"ja"},{"bibliographic_title":"Memoirs of Faculty of Engineering, University of Miyazaki","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Generally, the performance of a PV system depends not only on its basic technical characteristics but also on the environmental conditions in which they will be set up. Therefore, studying the effects of climatic parameters such as solar irradiance on the plane of array (GPOA), ambient temperature (Ta), relative humidity (RH) and wind speed (νa) on the performance of PV is vital to be able to utilize efficiently solar energy. \n The authors have studied the effects of various climatic parameters on the output performances of the two PV systems, 60 kW Copper Indium Gallium Selenide (CIGS) and 50 kW Multi-Crystalline Silicon (MC-Si), which were installed within the campus of University of Miyazaki, Japan. The main objectives of the research are to improve the prediction of the PV systems performance while knowing the climatic parameters of a particular area in which they stand, and also provide a useful dataset for the comparative studies.\n The analyses were done by the multiple linear regression analysis (MLR) using the statistical software R. The performances of the two PV systems are in positive proportion to the GPOA and νa, however, as per the values of the slopes of the regression equations, the MC-Si PV system is smaller than the CIGS PV system, attributed to their different module tilt angles and elevations of the PV sites. The performances are in negative proportion to the Ta, but the more sensitivity can be observed in the MC-Si PV system. The RH negatively affected on the MC-Si PV system, although its positive effects can be observed in the CIGS PV system.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宮崎大学工学部","subitem_publisher_language":"ja"},{"subitem_publisher":"Faculty of Engineering, University of Miyazaki","subitem_publisher_language":"en"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00732558","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"05404924","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Win, Kyaw Myo","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"Ota, Yasuyuki","creatorNameLang":"en"},{"creatorName":"太田, 靖之","creatorNameLang":"ja"},{"creatorName":"オオタ, ヤスユキ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nishioka, Kensuke","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sakoda, Tatsuya","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Hayashi, Noriyuki","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-11-12"}],"displaytype":"detail","filename":"Engineering_49_p119.pdf","filesize":[{"value":"2.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文","url":"https://miyazaki-u.repo.nii.ac.jp/record/6225/files/Engineering_49_p119.pdf"},"version_id":"ca41e8bf-2b71-42cd-9211-f76dcfe9f494"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Photovoltaics","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Performances","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Climatic Parameters","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Multiple Linear Regression","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Statistical Software R","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Multivariate Analysis Using R for Various Climatic Effects on the Output Performances of CIGS and Multi-Crystalline Si Photovoltaic Systems Installed in Miyazaki, Japan","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Multivariate Analysis Using R for Various Climatic Effects on the Output Performances of CIGS and Multi-Crystalline Si Photovoltaic Systems Installed in Miyazaki, Japan","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"5","path":["73","36","330","469"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-11-12"},"publish_date":"2020-11-12","publish_status":"0","recid":"6225","relation_version_is_last":true,"title":["Multivariate Analysis Using R for Various Climatic Effects on the Output Performances of CIGS and Multi-Crystalline Si Photovoltaic Systems Installed in Miyazaki, Japan"],"weko_creator_id":"5","weko_shared_id":-1},"updated":"2023-12-17T23:33:42.614105+00:00"}