{"created":"2023-05-15T10:01:26.522448+00:00","id":6020,"links":{},"metadata":{"_buckets":{"deposit":"5d961dab-cb04-4c74-893f-6bd1f0d26f4f"},"_deposit":{"created_by":5,"id":"6020","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"6020"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00006020","sets":["71","71:35"]},"author_link":["32143"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"248","bibliographicPageStart":"245","bibliographic_titles":[{"bibliographic_title":"International Conference on Science, Technology & Education (ICSTE 2016)","bibliographic_titleLang":"en"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This research aims at analyzing chopping current to variable of Transmission line arising from Transient Recovery Voltage which is the result of arc of rhythm of surface of electrical equipment such as circuit breaker by bringing parameter from short Transmission line, medium Transmission line, and Transmission sending line into the Transmission model. After that, a computer program was used to find current affecting surface of electrical equipment. The result of experiment could make it possible to know that the system of short Transmission line would affect the surface at most while the medium Transmission line and long Transmission line would affect less, respectively.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10003_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Norwrat, Rajsalee","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"32143","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-06-22"}],"displaytype":"detail","filename":"icste2016_p245.pdf","filesize":[{"value":"1.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文","url":"https://miyazaki-u.repo.nii.ac.jp/record/6020/files/icste2016_p245.pdf"},"version_id":"e42fa25d-7266-4571-85c8-8494a20ef27c"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"An Analysis of Chopping Current Affecting on Power Transmission Line","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"An Analysis of Chopping Current Affecting on Power Transmission Line","subitem_title_language":"en"}]},"item_type_id":"10003","owner":"5","path":["71","35"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-06-22"},"publish_date":"2020-06-22","publish_status":"0","recid":"6020","relation_version_is_last":true,"title":["An Analysis of Chopping Current Affecting on Power Transmission Line"],"weko_creator_id":"5","weko_shared_id":-1},"updated":"2024-10-03T06:09:33.759537+00:00"}