{"created":"2023-05-15T10:01:23.858539+00:00","id":5959,"links":{},"metadata":{"_buckets":{"deposit":"de59b47e-47ed-4190-bcc5-c106156cc55f"},"_deposit":{"created_by":5,"id":"5959","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"5959"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00005959","sets":["71","71:35"]},"author_link":["31949","31950","31951"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"194","bibliographicPageStart":"191","bibliographic_titles":[{"bibliographic_title":"International Conference on Applied Electrical and Mechanical Engineering 2019","bibliographic_titleLang":"en"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This study designs impulse voltage generator of 6 kV ,1.2/50 μs for testing low voltage electrical equipment according to IEC 60439 standard. This impulse generator is used to test conductor bar mate-rial in 3 Phase 4 Wire 400V. The conductor bars that are designed to withstand a voltage test at a fre-quency of resistance Impulse. Increasing the temperature according to the criteria and the resistance of the insulation can be used as a standard.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10003_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"W., Pheemsiriwattana","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31949","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"W, Boonpha","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31950","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"S., Manophan","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31951","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-06-21"}],"displaytype":"detail","filename":"icaeme2019_p191.pdf","filesize":[{"value":"474.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文","url":"https://miyazaki-u.repo.nii.ac.jp/record/5959/files/icaeme2019_p191.pdf"},"version_id":"b6c8b81e-4d35-40b2-a8df-0b557f25e035"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"A Study of Impulse Voltage Generator for Testing Low Voltage System","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A Study of Impulse Voltage Generator for Testing Low Voltage System","subitem_title_language":"en"}]},"item_type_id":"10003","owner":"5","path":["71","35"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-06-21"},"publish_date":"2020-06-21","publish_status":"0","recid":"5959","relation_version_is_last":true,"title":["A Study of Impulse Voltage Generator for Testing Low Voltage System"],"weko_creator_id":"5","weko_shared_id":-1},"updated":"2024-10-03T06:08:15.536353+00:00"}