{"created":"2023-05-15T10:01:23.245270+00:00","id":5945,"links":{},"metadata":{"_buckets":{"deposit":"101e01b8-1779-4d4b-a177-ae7965d220e2"},"_deposit":{"created_by":5,"id":"5945","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"5945"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00005945","sets":["71","71:35"]},"author_link":["31883","31884"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"130","bibliographicPageStart":"127","bibliographic_titles":[{"bibliographic_title":"International Conference on Applied Electrical and Mechanical Engineering 2019","bibliographic_titleLang":"en"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"It is well known that the ozone gas can be disinfected. On the other hand, if the ozone gas has a high concentration as result in harm to the body when inhaled. This research, the study of the relationship of gas flow rate and safety distance for human on disinfect bacteria with ozone generator from corona discharge technique with 20kHz frequency for ozone generator while the voltage ware 10 and 20 kV. In addition, the gas flow rate and the distance from generating point to measurement point for the study of the relationship were 0-10 L/min and 0-40 cm, respectively. It was found that, the gas flow rate ware not than 7L/min and the voltage were not than 20 kV can measure the concentration of the ozone was 0.1ppm. which harmless to the body from 30 cm distance at generating point. Besides, the generating point of ozone for treatment was the concentration of the ozone than 10 ppm. which sufficient for disinfect.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10003_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"N., Thungsuk","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"B., Suechoey","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-06-21"}],"displaytype":"detail","filename":"icaeme2019_p127.pdf","filesize":[{"value":"319.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文","url":"https://miyazaki-u.repo.nii.ac.jp/record/5945/files/icaeme2019_p127.pdf"},"version_id":"96d0aeb6-b1c0-4174-b243-2120d1d17ec5"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"A Case Study of Fabrication of Film with Spark Technique","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A Case Study of Fabrication of Film with Spark Technique","subitem_title_language":"en"}]},"item_type_id":"10003","owner":"5","path":["71","35"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-06-21"},"publish_date":"2020-06-21","publish_status":"0","recid":"5945","relation_version_is_last":true,"title":["A Case Study of Fabrication of Film with Spark Technique"],"weko_creator_id":"5","weko_shared_id":-1},"updated":"2023-07-29T11:41:45.466199+00:00"}