{"created":"2023-05-15T10:01:15.173707+00:00","id":5771,"links":{},"metadata":{"_buckets":{"deposit":"ed8d20d3-395d-4310-b35f-edf55467c668"},"_deposit":{"created_by":5,"id":"5771","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"5771"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00005771","sets":["71","71:35"]},"author_link":["505","26557","31052","197","31053","30970"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"188","bibliographicPageStart":"183","bibliographic_titles":[{"bibliographic_title":"International Conference on Science, Technology & Education (ICSTE 2018)","bibliographic_titleLang":"en"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This research aims to study the process to repair electric insulator, study the lifetime of the insulators were repaired, and insulator erosion rates were compared within the environment and period of usage by choosing to study especially electrical insulator in high voltage of electricity of Electricity Generating Authority that was removed from the system due to deficiencies in the area of The Electricity Generating Authority of Thailand in Suratthani. By electrical properties and mechanical properties qualifying examination of insulators has been approved. By electrical properties and mechanical properties qualifying testing of insulators has been approved. As the results showed that insulators have been improved by the process of insulators, qualifying values passed the standard test method ASTM A780-01 (2006).","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10003_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Siriwhat, Nilawat","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31052","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Somsak, Sanmuang","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31053","nameIdentifierScheme":"WEKO"}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"Arunrungrusmi, Somchai","creatorNameLang":"en"}],"familyNames":[{"familyName":"Arunrungrusmi","familyNameLang":"en"}],"givenNames":[{"givenName":"Somchai","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"505","nameIdentifierScheme":"WEKO"}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"Pakpoom, Chansri","creatorNameLang":"en"}],"familyNames":[{"familyName":"Pakpoom","familyNameLang":"en"}],"givenNames":[{"givenName":"Chansri","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"30970","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nuttee, Thungsuk","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"26557","nameIdentifierScheme":"WEKO"}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"Mungkung, Narong","creatorNameLang":"en"}],"familyNames":[{"familyName":"Mungkung","familyNameLang":"en"}],"givenNames":[{"givenName":"Narong","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"197","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-06-21"}],"displaytype":"detail","filename":"p183_icste2018.pdf","filesize":[{"value":"802.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文","url":"https://miyazaki-u.repo.nii.ac.jp/record/5771/files/p183_icste2018.pdf"},"version_id":"377e6a88-1f8e-4dae-b2fa-90ade6afbae6"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Electrical insulator, mechanical testing, electrical testing, standards ASTM A780-01(2006)","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Performance Analysis of Repaired High Voltage Insulators","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Performance Analysis of Repaired High Voltage Insulators","subitem_title_language":"en"}]},"item_type_id":"10003","owner":"5","path":["71","35"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-06-21"},"publish_date":"2020-06-21","publish_status":"0","recid":"5771","relation_version_is_last":true,"title":["Performance Analysis of Repaired High Voltage Insulators"],"weko_creator_id":"5","weko_shared_id":-1},"updated":"2024-10-03T06:24:28.495266+00:00"}