{"created":"2023-05-15T10:01:14.519376+00:00","id":5761,"links":{},"metadata":{"_buckets":{"deposit":"d5a47aec-6d68-481b-966c-14ff426cbd83"},"_deposit":{"created_by":5,"id":"5761","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"5761"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00005761","sets":["71","71:35"]},"author_link":["505","197","30970","31022","24","31027"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"128","bibliographicPageStart":"123","bibliographic_titles":[{"bibliographic_title":"International Conference on Science, Technology & Education (ICSTE 2018)","bibliographic_titleLang":"en"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Analysis and inspection of transformer quality for transformer type used hydrocarbon oil (Mineral oil) is Insulated. The oil is insulated in protect the short circuit in the transformer and heat the inside the transformer. Have Features between diesel and lubricant. Constantly checking the oil is key to the performance of the transformer it also extends the life of the transformer as well. The technique used to analyze and verify the quality of the Oil Type Transformer. In this article, the oil analysis method is used Dissolved gas analysis (DGA) and Online Partial Discharge. In order to increase the accuracy of the transformer's severity rating before the transformer insulation is damaged. It can also be used as a guideline for the maintenance and protection of the damage in a timely manner. Results have fault from the outside or inside the Transformer itself. Fault in the transformer is partial discharge With the Oil Analyze with Online Partial Discharge in Oil Type Transformer The result is a partial discharge inside the transformer. Both methods used in the analysis. The results are in the same direction.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10003_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Patcharaporn, Pitakpupa","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31022","nameIdentifierScheme":"WEKO"}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"Mungkung, Narong","creatorNameLang":"en"}],"familyNames":[{"familyName":"Mungkung","familyNameLang":"en"}],"givenNames":[{"givenName":"Narong","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"197","nameIdentifierScheme":"WEKO"}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"Arunrungrusmi, Somchai","creatorNameLang":"en"}],"familyNames":[{"familyName":"Arunrungrusmi","familyNameLang":"en"}],"givenNames":[{"givenName":"Somchai","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"505","nameIdentifierScheme":"WEKO"}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"Pakpoom, Chansri","creatorNameLang":"en"}],"familyNames":[{"familyName":"Pakpoom","familyNameLang":"en"}],"givenNames":[{"givenName":"Chansri","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"30970","nameIdentifierScheme":"WEKO"}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"0000000106573887","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"https://isni.org/isni/0000000106573887"}],"affiliationNames":[{"affiliationName":"宮崎大学","affiliationNameLang":"ja"},{"affiliationName":"University of Miyazaki","affiliationNameLang":"en"}]}],"creatorNames":[{"creatorName":"湯地, 敏史","creatorNameLang":"ja"},{"creatorName":"ユジ, トシフミ","creatorNameLang":"ja-Kana"},{"creatorName":"Yuji, Toshifumi","creatorNameLang":"en"},{"creatorName":"Yuji, Tosifumi","creatorNameLang":"en"}],"familyNames":[{"familyName":"湯地","familyNameLang":"ja"},{"familyName":"ユジ","familyNameLang":"ja-Kana"},{"familyName":"Yuji","familyNameLang":"en"},{"familyName":"Yuji","familyNameLang":"en"}],"givenNames":[{"givenName":"敏史","givenNameLang":"ja"},{"givenName":"トシフミ","givenNameLang":"ja-Kana"},{"givenName":"Toshifumi","givenNameLang":"en"},{"givenName":"Tosifumi","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"24","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"80418988","nameIdentifierScheme":"e-Rad_Researcher","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=80418988"}]},{"creatorNames":[{"creatorName":"Nattee, Thugsuk","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"31027","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-06-21"}],"displaytype":"detail","filename":"p123_icste2018.pdf","filesize":[{"value":"843.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文","url":"https://miyazaki-u.repo.nii.ac.jp/record/5761/files/p123_icste2018.pdf"},"version_id":"0e16fed2-3054-4fcc-816d-664bab8c03e4"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Dissolved gas analysis (DGA), Partial Discharge","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Oil Analyze with Online Partial Discharge in Oil Type Transformer","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Oil Analyze with Online Partial Discharge in Oil Type Transformer","subitem_title_language":"en"}]},"item_type_id":"10003","owner":"5","path":["71","35"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-06-21"},"publish_date":"2020-06-21","publish_status":"0","recid":"5761","relation_version_is_last":true,"title":["Oil Analyze with Online Partial Discharge in Oil Type Transformer"],"weko_creator_id":"5","weko_shared_id":2},"updated":"2024-11-15T07:34:21.500189+00:00"}