{"created":"2023-05-15T10:00:48.744192+00:00","id":5227,"links":{},"metadata":{"_buckets":{"deposit":"2f9977a6-18e0-447a-8e5f-21b2a483df8b"},"_deposit":{"created_by":5,"id":"5227","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"5227"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00005227","sets":["73","73:36","73:36:330","73:36:330:327"]},"author_link":["28317","14214","28318","12874","25486","28314"],"item_10002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"デ シカ ン ト クウチョウ システム ニ オケル ガイキ ノ ゼッタイ シツド ト システム ウンテン ホウシキ ト ノ カンケイ"}]},"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-07-31","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"184","bibliographicPageStart":"179","bibliographicVolumeNumber":"46","bibliographic_titles":[{"bibliographic_title":"宮崎大学工学部紀要","bibliographic_titleLang":"ja"},{"bibliographic_title":"Memoirs of Faculty of Engineering, University of Miyazaki","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Co-generation system has become an effective method to solve the global warming and energy problem.The system can achieve high efficiency both by using electric generation and by exhaust heat recovery. On the other hand, the development of the environmental improvement technology in a greenhouse is demanded agricultural sector. It is thought that a desiccant air conditioning system can solve these problems. In this paper, experiments aimed at establishing system operation methods according to absolute humidity of outside air were conducted. Firstly, the experiment was conducted with air volume of both blowers on dehumidification side and regeneration side set to 640 m3/h. As the result, it was confirmed that temperature and relative humidity inside the greenhouse could be controlled to target ranges of inside the greenhouse when absolute humidity of outside air is less than 17 g/kg. Secondly, the experiment was conducted when absolute humidity of outside air was very high.In this case, air volume of both blowers on dehumidification side and regeneration side were set to two different conditions. First condition of the blowers is 640 m3/h and another one is 740 m3/h. At the result, it was confirmed that setting the air volume of the blowers to 740 m3/h is better when absolute humidity of outside air is high.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宮崎大学工学部","subitem_publisher_language":"ja"},{"subitem_publisher":"Faculty of Engineering, University of Miyazaki","subitem_publisher_language":"en"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00732558","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"05404924","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"石川, 敏嗣","creatorNameLang":"ja"},{"creatorName":"イシカワ, トシツグ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"藤澤, 一平","creatorNameLang":"ja"},{"creatorName":"フジサワ, イッペイ","creatorNameLang":"ja-Kana"},{"creatorName":"Fujisawa, Ippei","creatorNameLang":"en"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"迫田, 達也","creatorNameLang":"ja"},{"creatorName":"サコダ, タツヤ","creatorNameLang":"ja-Kana"},{"creatorName":"Sakoda, Tatsuya","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"林, 則行","creatorNameLang":"ja"},{"creatorName":"ハヤシ, ノリユキ","creatorNameLang":"ja-Kana"},{"creatorName":"Hayashi, Noriyuki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ishikawa, Toshitsugu","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hujisawa, Ippei","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-06-21"}],"displaytype":"detail","filename":"p179.pdf","filesize":[{"value":"2.7 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文","url":"https://miyazaki-u.repo.nii.ac.jp/record/5227/files/p179.pdf"},"version_id":"856eaddd-73f5-4163-9823-a16b332e0992"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Co-generation, Dessicant air conditioning system, Greenhouse, Absolute humidity of outside, Air volume of blowers","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"デシカント空調システムにおける外気の絶対湿度とシステム運転方式との関係","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"デシカント空調システムにおける外気の絶対湿度とシステム運転方式との関係","subitem_title_language":"ja"},{"subitem_title":"Relationship between Absolute Humidity of Outside Air and System Operation Mode in Desiccant Air Conditioning System","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"5","path":["73","36","330","327"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-06-21"},"publish_date":"2020-06-21","publish_status":"0","recid":"5227","relation_version_is_last":true,"title":["デシカント空調システムにおける外気の絶対湿度とシステム運転方式との関係"],"weko_creator_id":"5","weko_shared_id":2},"updated":"2023-11-05T10:59:54.748768+00:00"}