{"created":"2023-05-15T09:58:56.245630+00:00","id":3001,"links":{},"metadata":{"_buckets":{"deposit":"bd738f3e-eaa6-448c-badc-eedf39aabb7e"},"_deposit":{"created_by":5,"id":"3001","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"3001"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00003001","sets":["73","73:36","73:36:330","73:36:330:314"]},"author_link":["15969","6697","15967","15965","6692","28"],"item_10002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"タイヨウコウ ハツデン (PV)-デンキ ブンカイ (EL)-ネンリョウ デンチ ハツデン (FC) クミアワセ システム ノ サイダイ シュツリョク ウンテン ホウホウ"}]},"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"226","bibliographicPageStart":"221","bibliographicVolumeNumber":"33","bibliographic_titles":[{"bibliographic_title":"宮崎大学工学部紀要","bibliographic_titleLang":"ja"},{"bibliographic_title":"Memoirs of Faculty of Engineering, University of Miyazaki","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Abstract \nSince the power output of photovoltaics (PV) is affected by natural conditions, a constant \npower output can not be obtained. So we have studied the PV-EL-FC hybrid system. We can \ngenerate and store hydrogen by electrolysis (EL) with the direct-current from a photovoltaic \ncell, and then supply the stored hydrogen to fuel cells (FCs) whenever the electric power \nneeded. \nIn this research, we examined the operation method for the maximum power output of the \nsystem . \nThe results are as follows: \n(1)We studied the fundamental characteristics of the PV-EL-FC hybrid system with the solar \nsimulator and sunlight. \n(2)In this system, the maxinwm power output could be obtained by controlling the resistivity \nof the electrolysis cells. \n(3)In the case of the amount of insolation change, the value of load resistivity of electrolysis \ncells is also followed to the insolation change. \n(4)The empirical formula of load resistivity of electrolysis cells could be derived, and the index \nof the optimal connection method of photovoltaics and electrolysis cells was obtained.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宮崎大学工学部","subitem_publisher_language":"ja"},{"subitem_publisher":"Faculty of Engineering, University of Miyazaki","subitem_publisher_language":"en"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00732558","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"05404924","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"熊谷, 広一","creatorNameLang":"ja"},{"creatorName":"クマガエ, コウイチ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"房野, 俊夫","creatorNameLang":"ja"},{"creatorName":"ボウノ, トシオ","creatorNameLang":"ja-Kana"},{"creatorName":"Bouno, Toshio","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"渡辺, 和也","creatorNameLang":"ja"},{"creatorName":"ワタナベ, カズヤ","creatorNameLang":"ja-Kana"},{"creatorName":"Watanabe, Kazuya","creatorNameLang":"en"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"大塚, 馨象","creatorNameLang":"ja"},{"creatorName":"オオツカ, ケイゾウ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kumagae, Kouichi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"渡辺, 和也","creatorNameLang":"ja"},{"creatorName":"ワタナベ, カズヤ","creatorNameLang":"ja-Kana"},{"creatorName":"Watanabe, Kazuya","creatorNameLang":"en"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ohtsuka, Keizou","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-06-21"}],"displaytype":"detail","filename":"KJ00002428246.pdf","filesize":[{"value":"951.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00002428246.pdf","url":"https://miyazaki-u.repo.nii.ac.jp/record/3001/files/KJ00002428246.pdf"},"version_id":"42b87ee8-fa21-4464-bf2c-b78a92b8c1f2"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Photovoltaic, Electrolysis cell, Fuel cell, Hybrid system, Maximum power output operation, Amount of insolation, Hydrogen","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"太陽光発電(PV)-電気分解(EL)-燃料電池発電(FC)組み合わせシステムの最大出力運転方法","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"太陽光発電(PV)-電気分解(EL)-燃料電池発電(FC)組み合わせシステムの最大出力運転方法","subitem_title_language":"ja"},{"subitem_title":"The study of maximum power output operation method of hte PV-EL-FC hybrid system","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"5","path":["73","36","330","314"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-06-28"},"publish_date":"2007-06-28","publish_status":"0","recid":"3001","relation_version_is_last":true,"title":["太陽光発電(PV)-電気分解(EL)-燃料電池発電(FC)組み合わせシステムの最大出力運転方法"],"weko_creator_id":"5","weko_shared_id":2},"updated":"2023-11-27T05:35:21.986667+00:00"}