{"created":"2023-05-15T09:58:52.630106+00:00","id":2926,"links":{},"metadata":{"_buckets":{"deposit":"8b7d506d-493d-4d1f-b554-e067150b4c2f"},"_deposit":{"created_by":5,"id":"2926","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"2926"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00002926","sets":["73","73:36","73:36:330","73:36:330:319"]},"author_link":["15505","15503","12679"],"item_10002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"タイヨウコウハツデン ノタメノ Ni-MH デンチ ジュウデン カイロ ノ セイギョ"}]},"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-09-30","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"187","bibliographicPageStart":"181","bibliographicVolumeNumber":"38","bibliographic_titles":[{"bibliographic_title":"宮崎大学工学部紀要","bibliographic_titleLang":"ja"},{"bibliographic_title":"Memoirs of Faculty of Engineering, University of Miyazaki","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Photovoltaic cells are expected to be introduced into electricity system as a dispersed power source. However, it is a serious problem that electric power perturbation of photovoltaic cells influences an entire electric power system. For this problem, it is a usual method to storage electric energy generated by storage batteries temporarily in storage battery. But, it is difficult to charge NiMH batteries from photovoltaic cells derectly with DC-DC converters, because photovoltaic cells and NiMH batteries have each the optimal operating point. Since this may drop efficency of the system, we add capacitors to circuit to prevent an efficiency decrease of the system. Capacitors can be charged and discharged rapidly, because current ratings of capacitors are higher than those of photovoltaic cells and NiMH batteries. In other words, we can charge with capacitors by the optimal operating point of photovoltaic cells. At the same time, we can charge with NiMH batteries at the optimal operating point for them. Then, we study the control method of these charge system. Especially, we study the control of the circuit for charging from capacitors into NiMH batteries.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宮崎大学工学部","subitem_publisher_language":"ja"},{"subitem_publisher":"Faculty of Engineering, University of Miyazaki","subitem_publisher_language":"en"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00732558","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"05404924","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"0000000106573887","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"https://isni.org/isni/0000000106573887"}],"affiliationNames":[{"affiliationName":"宮崎大学","affiliationNameLang":"ja"},{"affiliationName":"University of Miyazaki","affiliationNameLang":"en"}]}],"creatorNames":[{"creatorName":"穂高, 一条","creatorNameLang":"ja"},{"creatorName":"ホダカ, イチジヨウ","creatorNameLang":"ja-Kana"},{"creatorName":"Hodaka, chijo","creatorNameLang":"en"}],"familyNames":[{"familyName":"穂高","familyNameLang":"ja"},{"familyName":"ホダカ","familyNameLang":"ja-Kana"},{"familyName":"Hodaka","familyNameLang":"en"}],"givenNames":[{"givenName":"一条","givenNameLang":"ja"},{"givenName":"イチジヨウ","givenNameLang":"ja-Kana"},{"givenName":"chijo","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"12679","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"00293663","nameIdentifierScheme":"e-Rad_Researcher","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=00293663"}]},{"creatorNames":[{"creatorName":"輝, 直樹","creatorNameLang":"ja"},{"creatorName":"テル, ナオキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"15503","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Teru, Naoki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"15505","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-06-21"}],"displaytype":"detail","filename":"KJ00005630219.pdf","filesize":[{"value":"3.7 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00005630219.pdf","url":"https://miyazaki-u.repo.nii.ac.jp/record/2926/files/KJ00005630219.pdf"},"version_id":"38607814-4312-471f-968d-67e0d91df2d7"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Photovoltaic cells, Electric double, Nickel-Metal hydride battery, Circuit for charging","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"太陽光発電のためのNi-MH電池充電回路の制御","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"太陽光発電のためのNi-MH電池充電回路の制御","subitem_title_language":"ja"},{"subitem_title":"Control of NiMH batteries charge circuit for photovoltaic system","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"5","path":["73","36","330","319"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2009-10-30"},"publish_date":"2009-10-30","publish_status":"0","recid":"2926","relation_version_is_last":true,"title":["太陽光発電のためのNi-MH電池充電回路の制御"],"weko_creator_id":"5","weko_shared_id":2},"updated":"2025-01-10T02:16:55.995804+00:00"}