{"created":"2023-05-15T09:58:45.629397+00:00","id":2776,"links":{},"metadata":{"_buckets":{"deposit":"2a3831e3-5747-4b69-942b-9c534ddc1f10"},"_deposit":{"created_by":5,"id":"2776","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"2776"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00002776","sets":["73","73:36","73:36:330","73:36:330:320"]},"author_link":["14570","14575","14574","14569","7727","14571"],"item_10002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"ガラス センリョウケイ オヨビ ESR ドシメトリー オ モチイル ガンマセン ショウシャ ソウチ ノ ジカン イゾン ケンリョウセン サクセイ","subitem_alternative_title_language":"ja-Kana"}]},"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-09-30","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"41","bibliographicPageStart":"35","bibliographicVolumeNumber":"39","bibliographic_titles":[{"bibliographic_title":"宮崎大学工学部紀要","bibliographic_titleLang":"ja"},{"bibliographic_title":"Memoirs of Faculty of Engineering, University of Miyazaki","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Time-dependent calibration curve for the γ-ray irradiator was prepared using radiophoto -luminescence (RDPL) and ESR dosimetry. In RDPL measurement, the radiation dose was linearly increased until 38 Gy. However, above 38 Gy, it deviated upward. The ESR signal intensity of γ-irradiated L-α-alanine indicated linear in the range from 0 to 500 Gy. Though ESR signal intensity of L-α-alanine was saturated with the microwave power, the linearity of the calibration curve was reserved at any microwave power (< 5 mW). Summarizing these results, the time-dependent calibration curve was obtained using γ-irradiated L-α-alanine in the range of 0 - 500 Gy after correction by RDPL for the radiation dose below 38 Gy.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宮崎大学工学部","subitem_publisher_language":"ja"},{"subitem_publisher":"Faculty of Engineering, University of Miyazaki","subitem_publisher_language":"en"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00732558","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"05404924","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"中島, 暉","creatorNameLang":"ja"},{"creatorName":"ナカジマ, アキラ","creatorNameLang":"ja-Kana"},{"creatorName":"Nakajima, Akira","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"長田, 栄二","creatorNameLang":"ja"},{"creatorName":"オサダ, エイジ","creatorNameLang":"ja-Kana"},{"creatorName":"Osada, Eiji","creatorNameLang":"en"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"松田, 恵美子","creatorNameLang":"ja"},{"creatorName":"マツダ, エミコ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"松田, 達郎","creatorNameLang":"ja"},{"creatorName":"マツダ, タツロウ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{},{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"長田, 栄二","creatorNameLang":"ja"},{"creatorName":"オサダ, エイジ","creatorNameLang":"ja-Kana"},{"creatorName":"Osada, Eiji","creatorNameLang":"en"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsuda, Emiko","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsuda, Tatsuro","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-06-21"}],"displaytype":"detail","filename":"engineering39-07.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"engineering39-07.pdf","url":"https://miyazaki-u.repo.nii.ac.jp/record/2776/files/engineering39-07.pdf"},"version_id":"580eba14-745a-4aea-94cb-d9b10e0421b6"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"ESR dosimetry, L-α-alanine, Radiophotoluminescence, Time-depentent calibration curve, γ-ray irradiator","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ガラス線量計及びESR ドシメトリーを用いるγ線照射装置の時間依存検量線作成","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ガラス線量計及びESR ドシメトリーを用いるγ線照射装置の時間依存検量線作成","subitem_title_language":"ja"},{"subitem_title":"Depiction of Time-dependent Calibration Curve for y-Ray Irradiater Using Radiophotoluminescence and ESR Dosimetry","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"5","path":["73","36","330","320"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2011-02-25"},"publish_date":"2011-02-25","publish_status":"0","recid":"2776","relation_version_is_last":true,"title":["ガラス線量計及びESR ドシメトリーを用いるγ線照射装置の時間依存検量線作成"],"weko_creator_id":"5","weko_shared_id":2},"updated":"2023-12-12T00:37:15.828415+00:00"}