{"created":"2023-05-15T09:58:45.370401+00:00","id":2772,"links":{},"metadata":{"_buckets":{"deposit":"8f7c6c8d-ff09-4f1a-8118-d10f74d1e35c"},"_deposit":{"created_by":5,"id":"2772","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"2772"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00002772","sets":["73","73:36","73:36:330","73:36:330:324"]},"author_link":["14552","14214","14624"],"item_10002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"セッショク デンリュウ オ モギ シタ セイタイ モデルナイ ニオケル ユウドウ デンカイ ノ ケイソク","subitem_alternative_title_language":"ja-Kana"}]},"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-07-31","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"48","bibliographicPageStart":"43","bibliographicVolumeNumber":"43","bibliographic_titles":[{"bibliographic_title":"宮崎大学工学部紀要","bibliographic_titleLang":"ja"},{"bibliographic_title":"Memoirs of Faculty of Engineering, University of Miyazaki","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"It is necessary to assume a case in which human with a medical device made of metal (cardiac pacemaker, intramedullary nail etc.), experience electrical shock. Modelling of a medical device inside a model of human body and calculating a contact current inside the model one strongly demanded.\nIn this study, we aimed to establish a technique to evaluate the precision of the calculation model including the metal body in human body. As this method, we selected a method for measuring the induced electric field inside the human model simulating the contact current. Constructing a system for the measurement and preparing two kinds of human models, we measured induced electric field inside the model. We confirmed the validity of this measurement system in comparison with the calculation result by the modified SPFD method result. As the result, it was found that our proposed system could measure the induced electric field with high accuracy.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宮崎大学工学部","subitem_publisher_language":"ja"},{"subitem_publisher":"Faculty of Engineering, University of Miyazaki","subitem_publisher_language":"en"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00732558","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"05404924","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"青木, 秀幸","creatorNameLang":"ja"},{"creatorName":"アオキ, ヒデユキ","creatorNameLang":"ja-Kana"},{"creatorName":"Aoki, Hideyuki","creatorNameLang":"en"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"太良尾, 浩生","creatorNameLang":"ja"},{"creatorName":"タラオ, ヒロオ","creatorNameLang":"ja-Kana"},{"creatorName":"Tarao, Hiroo","creatorNameLang":"en"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"林, 則行","creatorNameLang":"ja"},{"creatorName":"ハヤシ, ノリユキ","creatorNameLang":"ja-Kana"},{"creatorName":"Hayashi, Noriyuki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"青木, 秀幸","creatorNameLang":"ja"},{"creatorName":"アオキ, ヒデユキ","creatorNameLang":"ja-Kana"},{"creatorName":"Aoki, Hideyuki","creatorNameLang":"en"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"太良尾, 浩生","creatorNameLang":"ja"},{"creatorName":"タラオ, ヒロオ","creatorNameLang":"ja-Kana"},{"creatorName":"Tarao, Hiroo","creatorNameLang":"en"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-06-21"}],"displaytype":"detail","filename":"engineering43_43-48.pdf","filesize":[{"value":"576.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"engineering43_43-48.pdf","url":"https://miyazaki-u.repo.nii.ac.jp/record/2772/files/engineering43_43-48.pdf"},"version_id":"94b4f4f2-6b8d-48fa-819b-e77d61aac75d"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Electrical safety, Human model, Metal body, Contact current, Modified SPFD method, Low frequency, Induced electric field","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"接触電流を模擬した生体モデル内における誘導電界の計測","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"接触電流を模擬した生体モデル内における誘導電界の計測","subitem_title_language":"ja"},{"subitem_title":"Measurement Technique of Induced Electric Field inside the Human Model to Simulate Contact Current","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"5","path":["73","36","330","324"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2014-09-03"},"publish_date":"2014-09-03","publish_status":"0","recid":"2772","relation_version_is_last":true,"title":["接触電流を模擬した生体モデル内における誘導電界の計測"],"weko_creator_id":"5","weko_shared_id":2},"updated":"2023-11-20T05:37:48.647177+00:00"}