{"created":"2023-05-15T09:58:44.718418+00:00","id":2758,"links":{},"metadata":{"_buckets":{"deposit":"bff2821a-3390-4d30-911f-8ce06b415729"},"_deposit":{"created_by":5,"id":"2758","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"2758"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00002758","sets":["73","73:36","73:36:330","73:36:330:322"]},"author_link":["6256","6286","6257","14457","14461"],"item_10002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"ヒバナ テンカ キカン ネンショウシツ ニ オケル ネツリュウソク ケイソク シリンダナイ ナガレ ガ テイリュウソクイキ デノ ケントウ","subitem_alternative_title_language":"ja-Kana"}]},"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-07-30","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"186","bibliographicPageStart":"181","bibliographicVolumeNumber":"41","bibliographic_titles":[{"bibliographic_title":"宮崎大学工学部紀要","bibliographic_titleLang":"ja"},{"bibliographic_title":"Memoirs of Faculty of Engineering, University of Miyazaki","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"As a method of high efficiecy of an internal combustion engine a gas flow is introduced into a combustion chamber. However, the gas flow in the combustion chamber is not necessarily connected efficient from increasing the cooling loss by the heat transfer between the combustion gas and the combustion chamber wall. Therefore, it is necessary to know the correlation of the gas flow in the cylinder and heat transfer to the combustion chamber wall. When the state of the gas flow in the cylinder is swirl, the equation which can calculate the heat transfer coefficient of the whole combustion chamber from the gas flow within the turbulent flow region is obtained. However, this equation cannot be used when a gas flow is in the low flow velocity region. In this study, the heat flux on the cylinder wall is measured in the low flow velocity region. As a result, the heat transfer coefficient within the low flow velocity region is obtained using the pressure and the volume in the cylinder.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宮崎大学工学部","subitem_publisher_language":"ja"},{"subitem_publisher":"Faculty of Engineering, University of Miyazaki","subitem_publisher_language":"en"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00732558","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"05404924","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"笹井, 孝志","creatorNameLang":"ja"},{"creatorName":"ササイ, タカシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"長瀬, 慶紀","creatorNameLang":"ja"},{"creatorName":"Nagase, Yoshinori","creatorNameLang":"en"},{"creatorName":"長瀬, 慶記","creatorNameLang":"ja"},{"creatorName":"ナガセ, ヨシノリ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{},{}],"givenNames":[{},{},{},{}],"nameIdentifiers":[{},{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"Tomomatsu, Shigeki","creatorNameLang":"en"},{"creatorName":"友松, 重樹","creatorNameLang":"ja"},{"creatorName":"トモマツ, シゲキ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"Kimura, Masatoshi","creatorNameLang":"en"},{"creatorName":"木村, 正寿","creatorNameLang":"ja"},{"creatorName":"キムラ, マサトシ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sasai, Takashi","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-06-21"}],"displaytype":"detail","filename":"engineering41_181-186.pdf","filesize":[{"value":"848.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"engineering41_181-186.pdf","url":"https://miyazaki-u.repo.nii.ac.jp/record/2758/files/engineering41_181-186.pdf"},"version_id":"76255c81-dfc2-49f6-907e-dd1c326f32d1"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Engine, Heat flux, Gas flow, Heat transfer coefficient, Swirl","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"火花点火機関燃焼室における熱流束計測(シリンダ内流れが低流速域での検討)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"火花点火機関燃焼室における熱流束計測(シリンダ内流れが低流速域での検討)","subitem_title_language":"ja"},{"subitem_title":"Measurement of Heat Flux on Combustion Chamber of Spark Ignition Engine (Examination of Low Velocity of in Cylinder Flow)","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"5","path":["73","36","330","322"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2012-11-01"},"publish_date":"2012-11-01","publish_status":"0","recid":"2758","relation_version_is_last":true,"title":["火花点火機関燃焼室における熱流束計測(シリンダ内流れが低流速域での検討)"],"weko_creator_id":"5","weko_shared_id":2},"updated":"2023-09-02T13:04:21.172133+00:00"}