{"created":"2023-05-15T09:58:29.221030+00:00","id":2452,"links":{},"metadata":{"_buckets":{"deposit":"3ac6e53e-5aee-4395-ac13-78580f290ee8"},"_deposit":{"created_by":5,"id":"2452","owner":"5","owners":[5],"pid":{"revision_id":0,"type":"depid","value":"2452"},"status":"published"},"_oai":{"id":"oai:miyazaki-u.repo.nii.ac.jp:00002452","sets":["73","73:36","73:36:330","73:36:330:316"]},"author_link":["12379","1678","6637","6647","12383"],"item_10002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"コタイ コウブンシケイ ネンリョウ デンチ ノ カシツ ジョウケン ノ ケントウ","subitem_alternative_title_language":"ja-Kana"}]},"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-08-30","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"100","bibliographicPageStart":"95","bibliographicVolumeNumber":"35","bibliographic_titles":[{"bibliographic_title":"宮崎大学工学部紀要","bibliographic_titleLang":"ja"},{"bibliographic_title":"Memoirs of Faculty of Engineering, University of Miyazaki","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Abstract \nEnvironmental problems have become aggravated by consuming the fossil energy. Then, \nthe fuel cell that doesn't exhaust carbon dioxide is paid to attention. As for Polymer \nElectrolyte Fuel Cell (PEFC), the water management is a noteworthy problem. The method of \nexternal humidification is coupled with the systems configuration increasing. It is thought \nthat the generated water is able to keep the water content of membrane when a reactant gas is \nsupplied to the PEFC by counter flow. In this study, the performance of PEFC is examined in \ncases of counter flow and parallel flow, Iow humidified condition and dry condition. Both \nlow humidified condition and dry condition obtained a high power density with case of the \ntemperature of the cell at 50℃ or less. Moreover, the similar performance under counter flow \nand parallel flow both at low humidified condition was obtained. When we operate the cell \nfor a long time, the cell voltage was able to be maintained by changing the air of utilization \nrate .","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宮崎大学工学部","subitem_publisher_language":"ja"},{"subitem_publisher":"Faculty of Engineering, University of Miyazaki","subitem_publisher_language":"en"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00732558","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"05404924","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"越智, 祥文","creatorNameLang":"ja"},{"creatorName":"オチ, ヨシフミ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"田島, 大輔"},{"creatorName":"タジマ, ダイスケ","creatorNameLang":"ja-Kana"},{"creatorName":"Tashima, Daisuke","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"大坪, 昌久","creatorNameLang":"ja"},{"creatorName":"オオツボ, マサヒサ","creatorNameLang":"ja-Kana"},{"creatorName":"Otsubo, Masahisa","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"本田, 親久","creatorNameLang":"ja"},{"creatorName":"ホンダ, チカヒサ","creatorNameLang":"ja-Kana"},{"creatorName":"Honda, Chikahisa","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ochi, Yoshifumi","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-06-21"}],"displaytype":"detail","filename":"KJ00004439495.pdf","filesize":[{"value":"683.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00004439495.pdf","url":"https://miyazaki-u.repo.nii.ac.jp/record/2452/files/KJ00004439495.pdf"},"version_id":"3aff6c33-6d80-4a4d-9883-4b2453855a18"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"PEFC, water management, without humidifier, counter flow, parallel flow","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"固体高分子形燃料電池の加湿条件の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"固体高分子形燃料電池の加湿条件の検討","subitem_title_language":"ja"},{"subitem_title":"Consideration of a Polymer Electrolyte Fuel Cell Under Low Humidified Condition","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"5","path":["73","36","330","316"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-06-28"},"publish_date":"2007-06-28","publish_status":"0","recid":"2452","relation_version_is_last":true,"title":["固体高分子形燃料電池の加湿条件の検討"],"weko_creator_id":"5","weko_shared_id":2},"updated":"2023-07-30T08:25:25.600178+00:00"}