WEKO3
アイテム
Three-Dimensional Imaging Sensor-Based Non-Contact Measurement of Neonatal Head Circumference in Incubators
http://hdl.handle.net/10458/0002001310
http://hdl.handle.net/10458/00020013103550cfc4-d53d-4f23-8a78-a6e71d81fcd1
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
| アイテムタイプ | 学術雑誌論文 / Journal Article(1) | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2025-05-25 | |||||||||||||||||||
| タイトル | ||||||||||||||||||||
| タイトル | Three-Dimensional Imaging Sensor-Based Non-Contact Measurement of Neonatal Head Circumference in Incubators | |||||||||||||||||||
| 言語 | en | |||||||||||||||||||
| 言語 | ||||||||||||||||||||
| 言語 | eng | |||||||||||||||||||
| キーワード | ||||||||||||||||||||
| 言語 | en | |||||||||||||||||||
| キーワード | 3D imaging sensor | |||||||||||||||||||
| キーワード | ||||||||||||||||||||
| 言語 | en | |||||||||||||||||||
| キーワード | head circumference | |||||||||||||||||||
| キーワード | ||||||||||||||||||||
| 言語 | en | |||||||||||||||||||
| キーワード | incubator | |||||||||||||||||||
| キーワード | ||||||||||||||||||||
| 言語 | en | |||||||||||||||||||
| キーワード | mat | |||||||||||||||||||
| キーワード | ||||||||||||||||||||
| 言語 | en | |||||||||||||||||||
| キーワード | newborns | |||||||||||||||||||
| 資源タイプ | ||||||||||||||||||||
| 資源タイプ | journal article | |||||||||||||||||||
| アクセス権 | ||||||||||||||||||||
| アクセス権 | open access | |||||||||||||||||||
| 著者 |
Win, Khin Dagon
× Win, Khin Dagon
× 川末, 紀功仁
WEKO
5637
× 金子, 政時
WEKO
24696
|
|||||||||||||||||||
| 抄録 | ||||||||||||||||||||
| 内容記述タイプ | Abstract | |||||||||||||||||||
| 内容記述 | In Japan, birth rates are declining, but there are a rising number of underweight newborns who require specialized care in neonatal intensive care units (NICUs). Head circumference is an important indicator of brain development for low-birth-weight infants. However, measuring head circumference requires extreme care because low-birth-weight infants have fragile skin. Therefore, a non-contact measurement system using a 3D imaging sensor was developed. Using this system, three-dimensional data for a newborn’s head can be obtained from outside the incubator. Briefly, the images are taken from above the incubator, so there is an area behind the head that cannot be captured by the camera, but the head circumference estimation takes into account the fact that the head is in contact with the mat. The proposed method allows head circumference estimation without touching the newborn. This approach minimizes stress for both the neonate and the nurse and improves efficiency and safety in the NICU. | |||||||||||||||||||
| 言語 | en | |||||||||||||||||||
| bibliographic_information |
en : Sensors 巻 25, 号 6, p. 1869, 発行日 2025-03-01 |
|||||||||||||||||||
| 出版者 | ||||||||||||||||||||
| 出版者 | MDPI AG | |||||||||||||||||||
| 言語 | en | |||||||||||||||||||
| ISSN | ||||||||||||||||||||
| 収録物識別子タイプ | EISSN | |||||||||||||||||||
| 収録物識別子 | 14248220 | |||||||||||||||||||
| item_10001_relation_14 | ||||||||||||||||||||
| 関連タイプ | isVersionOf | |||||||||||||||||||
| 識別子タイプ | DOI | |||||||||||||||||||
| 関連識別子 | https://doi.org/10.3390/s25061869 | |||||||||||||||||||
| 権利 | ||||||||||||||||||||
| 権利情報 | © 2025 by the authors. | |||||||||||||||||||
| 言語 | en | |||||||||||||||||||
| 出版タイプ | ||||||||||||||||||||
| 出版タイプ | VoR | |||||||||||||||||||