The purpose of this study is to estimate a long-term reliability of activated carbon made from coffee grounds. Long-term cycle test under steady state in aqueous electrolyte was performed using cyclic voltammetry (CV) method. And, cycle test by CV method in case of the over voltage test was performed. As the result, although capacitance after the long-term cycle test was almost the same before the cycle test, decrease of capacitance was caused at initial cycle in the over voltage test. Finally, deterioration occurred at 3000 cycles. Therefore, it was understood that durability of activated carbon made from coffee grounds to the over voltage is seemed to be low.
雑誌名
宮崎大學工學部紀要
巻
43
ページ
63 - 68
発行年
2014-07-31
出版者
宮崎大学工学部
Miyazaki University
Faculty of Engineering, University of Miyazaki